Micromeritics Asap 2020 Software

Micromeritics’ ASAP 2020 HD Accelerated Surface Area and Porosity Analyzer was recognized as one of the best new products introduced to the China marketplace in 2011, at a recent Particle Measurement Committee meeting of the China Particuology Society in Chengdu, China.
After considering applications from numerous manufacturers, China Powder and the Beijing Powder Technology Association presented their first annual Excellent Product Award to Micromeritics Instrument (Shanghai) Ltd.

Micromeritics asap 2020 software update

Micromeritics ASAP 2020 HD includes many features that offer improved isotherm resolution and accuracy. Wider pressure measurement capabilities provide more resolution and new options for materials with micropores like metal organic frameworks, activated carbons, and zeolites. New low pressure desorption capabilities are beneficial to material scientists who synthesize materials that exhibit adsorbed phase changes during desorption.

About the Program. Read more about the Army Drug Testing Program. DTP Software and User Manual. The DoD Drug Testing Program (DTP) version 5.4k replaces all previous versions of of the full DTP software; DTPLiteUSA1 (version 5.4.1) replaces all previous versions of DTP Lite. Micromeritics’ staff of scientists can help you determine how the ASAP 2020 can be used for your application. New ASAP 2020 version 3.00 software provides options specifically designed to help fuel cell and hydrogen storage researchers. MICROMERITICS if, at the request of the purchaser, MICROMERITICS modifies a standard product or manu- Provides a general description of the ASAP 2020 system as well as its Equipment Description ASAP 2020 Confirm. The Micromeritics ASAP 2020 Plus integrates a variety of automated gas sorption techniques into a single, but powerful, table top instrument. The system is designed to provide high-quality surface area, porosity, and chemisorption isotherm data to materials analysis laboratories with ever-expanding analytical requirements. ASAP 2020 Software Features The easy-to-use ASAP 2020 software utilizes a Windows interface that includes Wizards and applications to help plan, launch, and control the analysis. You can collect, organize, archive and reduce raw data, and store standardized sample infor-mation and analysis conditions for easy access during later applications.

Hi-AC (Higher resolution Adsorbed phase Calculations) technology features the precision fluid properties developed by the National Institute of Standards and Technology combined with rigorous free-space control, the real gas equation of state, and compensation for the dynamic void space. Proprietary temperature control for the chemisorption option provides benefits across the entire temperature range on the ASAP 2020 HD, including improved precision near ambient temperature where it is often the most difficult to control temperature.
A large ASAP 2020 HD adsorptive properties library allows users to conveniently select new probe molecules without the worries or difficulties of finding fluid property data.

This library provides the Hi-AC method all fundamental fluid properties in high resolution. The user also has the convenience of high resolution with the click of a button. With the most comprehensive selection of DFT/NLDFT models for textural analysis, the current Micromeritics collection includes more than 20 models that cover a range of materials, geometries, and adsorptives. Micromeritics instrument users can select a model that best describes their material.
ASAP 2020 users can also benefit from these new capabilities by upgrading their current instrument to the new HD standard.

Description

Micromeritics Asap 2020 Software Review

Micromeritics’ ASAP 2020 Accelerated Surface Area and Porosimetry analyzer uses the gas sorption technique to generate high-quality data for research and quality control applications. Available options include the micropore option, the high-vac option, and the chemisorption option, which uses the static volumetric technique to determine the percent metal dispersion, active metal surface area, size of active particles, and surface acidity of catalyst materials. Data obtained by an ASAP 2020 analyzer are used to achieve efficiency, safety, quality, and profitability in any modern materials-oriented work, and can be used by scientists with confidence and assurance.
Uses of the ASAP 2020
The ASAP 2020 is used to monitor catalysts converting a stream of feedstock chemicals into a product, activated carbon used for the recovery of precious metals from a mining process solution, a pharmaceutical tablet as it undergoes dissolution and absorption at just the right dosing rate, and production of ceramics made from an exacting combination of finely powdered raw materials. Micromeritcs’ staff of scientists and engineers can help you determine how the ASAP 2020 can be used for your application.

Micromeritics Asap 2020 Software Download

Features

  • Two Independent vacuum systems that allow preparation and analysis to proceed concurrently
  • Oil-free “dry” vacuum option to prevent oil contamination
  • Two-station intelligent degas system for fully automated degassing with controlled heating time profiles
  • long-duration cryogen system for unattended analyses
  • Twelve gas inlets that are automatically selectable to allow for automated selection of pretreatment, backfill, and analysis gases, and the ability to connect to a mass spectrometer

Analysis Technique

The basics of the analytical technique are simple; a sample contained in an evacuated sample tube is cooled (typically) to cryogenic temperature, then is exposed to analysis gas at a series of precisely controlled pressures. With each incremental pressure increase, the number of gas molecules adsorbed on the surface increases. The pressure at which adsorption equilibrium occurs is measured and the universal gas law is applied to determine the quantity of gas adsorbed.
As adsorption proceeds, the thickness of the adsorbed film increases. Any micropores in the surface are quickly filled, then the free surface becomes completely covered, and finally larger pores are filled. The process may continue to the point of bulk condensation of the analysis gas. Then, the desorption process may begin in which pressure systematically is reduced resulting in liberation of the adsorbed molecules. As with the adsorption process, the changing quantity of gas on the solid surface is quantified. These two sets of data describe the adsorption and desorption isotherms. Analysis of the isotherms yields information about the surface characteristics of the material.

Micromeritics Asap 2020 Software Update

Specification

Micromeritics Asap 2020 Software Download

Pressure Measurement:Range: 0 to 950 mmHg
Resolution:
  • 1000-mmHg Transducer: 0.001 mmHg
  • 10-mmHg Transducer*: 0.00001 mmHg
  • 1-mmHg Transducer**: 0.000001 mmHg (optional for expanded resolution)
Accuracy (Analysis System Only):
Includes nonlinearity, hysteresis, and nonrepeatability. Transducer manufacturer’s specifications.
  • 1000-mmHg Range: within 0.15% of reading (analysis system only)
  • 10-mmHg Range*: within 0.15% of reading
  • 1-mmHg Range**: within 0.12% of reading
System Capacity:Sample Preparation: 2 integrated degas ports
Analysis: 1 sample port and 1 saturation pressure tube
Up to 2 complete analysis units can be independently controlled by 1 computer
Vacuum System:Degas: Either two-stage, oil sealed, mechanical vacuum pump, 5 x 10-3 mmHg ultimate vacuum or high vacuum system ultimate vacuum <10-8 mbar
Analysis – Nitrogen system: two stage, oil sealed mechanical vacuum pump, 5 x 10-3 mmHg ultimate vacuum.
Multigas and Micropore: High vac system, ultimate <10-8 mbar.
Degas System:Temperature Range: Ambient to 450 ºC(Programmable)
Temperature Selection: Digitally set, 1 ºC increments
Accuracy: Deviation less than +/- 10 ºC of set point at thermocouple
Backfill Gas: User-selectable, typically nitrogen or helium
Cryogen System:Patented Isothermal Jackets effectively maintain cryogen level constant on sample tube and P0 tube during analysis as evaporation of cryogen occurs.
Capacity: 3-Liter Dewar, which provides up to 72 hours of unattended analysis.
Analysis Time: Unlimited. Cryogen Dewars may be refilled without affecting the accuracy of results
Sample Size:Sample tubes are available for various size pellets, cores, and powders. Sample tube stems are 1/2-in.(1.27-cm) OD with 9-cm3 bulbs, 1/4-in. (0.635-cm) or 3/8-in. (0.953-cm) OD stems with 9-cm3 bulbs. Special tubes can be designed.
Electrical:Voltage: 100, 115, 230 VAC +/-10%
Frequency: 50/60 Hz
Power: 700 VA, operating (maximum)
Physical:Height: 99 cm (39 in.)
Width: 85 cm (33.5 in.)
Depth: 61 cm (24 in.)
Weight: 115 kg (250 lbs)
Miscellaneous:ISO 9001 manufacturer , CE certified

Comments are closed.